Kalstein

Understanding the Environmental Conditions and Installation Requirements for the YR06196 Digital Veterinary Intraoral X-ray System

By Kalstein · Published on:

Category:articulos-de-productos

Understanding the Environmental Conditions and Installation Requirements for the YR06196 Digital Veterinary Intraoral X-ray System

Explore the essential environmental conditions and installation requirements for the YR06196 Digital Veterinary Intraoral X-ray System, ensuring optimal perform

3D available

Understanding the Environmental Conditions and Installation Requirements for the YR06196 Digital Veterinary Intraoral X-ray System

The YR06196 Digital Veterinary Intraoral X-ray System is designed for effective imaging and diagnostic purposes in veterinary practices. Its performance is not only reliant on its advanced technology but also significantly influenced by the surrounding environmental conditions and proper installation requirements. This article delves into the critical site preparation and installation parameters necessary for the optimal operation of the YR06196.

Technical Specifications of the YR06196

SpecificationDetails
ModelYR06196
Power Supply220V±10%, 50HZ, 1KVA
Tube Voltage70 kVp
Tube Current8 mA
Focus Size0.8 mm
Total Filtration2.5 mmAL
Exposure Time0.2-4s
Leak RadiationOutside one meter ≤ 0.002Mg/h (national standard: 0.25Mg/h)
Package Size152×57×26 (cm)
Net Weight57 kg
Chip TypeCMOS APS
Fiber Optic PlateYes
ScintillatorGOS
Dimension39×28.5mm
Active Area30×22.5mm
Pixel Size18.5µm
Pixels1600*1200
Resolution14-20Ip/mm
Power Consumption600 mW

Environmental Conditions for Optimal Operation

Understanding the environmental requirements is crucial for the effective operation of the YR06196. Factors such as temperature, humidity, and power stability must be taken into account:

  • Temperature: The system operates best within a temperature range of 15°C to 30°C. Extreme temperatures can affect the performance and imaging quality.
  • Humidity: Ideal relative humidity should be maintained between 40% and 60% to prevent moisture-related damages or malfunctions.
  • Power Stability: The YR06196 requires a stable power supply of 220V±10%. Fluctuations can lead to equipment failure and inaccurate readings.

Installation Requirements for the YR06196

Proper installation is vital for the YR06196 to function correctly and provide high-quality imaging. Follow these installation guidelines:

  • Location: Choose a well-ventilated area, free from excessive dust and vibration. Ensure there is adequate space for operation and maintenance.
  • Anchoring: Securely anchor the unit to prevent movement during use, which can affect imaging accuracy.
  • Power Connection: Ensure a dedicated electrical outlet is available, and verify the voltage before connecting to avoid damage.
  • Network Setup: For systems integrating with digital imaging, configure the network settings as per the manufacturer's guidelines.

Common Installation Mistakes to Avoid

New users may encounter several common mistakes during installation:

  • Failing to check power supply specifications, leading to possible equipment damage.
  • Improper placement in areas with high humidity or extreme temperatures.
  • Neglecting to secure the system properly, resulting in inaccurate images.

Site Preparation Checklist

Checklist ItemStatus
Verify electrical supply meets specifications (220V±10%)[ ]
Ensure a stable temperature range (15°C to 30°C)[ ]
Confirm humidity levels (40% to 60%)[ ]
Prepare adequate space for operation[ ]
Securely anchor the unit[ ]
Check network connectivity for digital imaging[ ]

Frequently Asked Questions

What are the ideal environmental conditions for the YR06196 X-ray system?

The YR06196 operates best in a temperature range of 15°C to 30°C and at a relative humidity between 40% and 60%. These conditions help ensure optimal performance and longevity.

What should be included in the installation process for the YR06196?

Installation should include verifying electrical specifications, ensuring proper placement in a ventilated area, securing the unit, and configuring network settings if connecting to digital imaging systems.

How can improper installation affect the YR06196's performance?

Improper installation can lead to equipment malfunctions, inaccurate imaging, and potential damage to the X-ray system, adversely affecting its diagnostic capabilities.

What are common troubleshooting issues with the YR06196?

Common issues include power supply fluctuations, incorrect imaging results due to poor anchoring, and connectivity problems with digital systems, all of which can be resolved by following the installation guidelines carefully.

How often should the YR06196 be maintained?

Regular maintenance checks are recommended every six months to ensure the equipment remains in good working order and continues to provide accurate imaging results.

What type of power supply is required for the YR06196?

The YR06196 requires a stable power supply of 220V±10% at 50Hz. It is crucial to use a dedicated outlet to avoid fluctuations that could damage the equipment.

How can I ensure optimal imaging performance with the YR06196?

To ensure optimal imaging performance, maintain the recommended environmental conditions, perform regular maintenance, and ensure correct installation according to the manufacturer’s guidelines.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Digital Veterinary Intraoral X-ray System YR06196 with all specifications, dimensions, accessories and quote options.
View product datasheet →