    Description

    Biomedical Liquid Nitrogen Storage Solutions YR05423 // YR05437 offer state-of-the-art LN2 storage solutions, designed to meet the needs of demanding biomedical environments. These robust storage containers, available in capacities ranging from 5 to 500 liters, use innovative technology to utilize the pressure generated by a small amount of vaporized liquid nitrogen for efficient discharge. Constructed entirely of welded stainless steel, these units feature a variety of safety mechanisms, ensuring reliable performance and safe storage.

    Price in the Market

    The Biomedical Liquid Nitrogen Storage Solutions are competitively priced within the market range, with prices typically spanning from USD 11,095 to USD 11,895, depending on specific model capacities and additional features. This pricing ensures that organizations of varying sizes can afford advanced LN2 storage solutions that meet their specific needs.

    Frequently Asked Questions

    • What is the warranty period for these storage units? Each unit comes with a 5-year vacuum warranty, guaranteeing high performance and durability.
    • Can these containers operate in harsh environments? Yes, the all-welded stainless steel construction is designed to withstand challenging conditions, making them ideal for various industrial and biomedical applications.
    • Are there different model capacities available? Yes, the units are available in multiple capacities ranging from 5 to 500 liters, catering to diverse storage needs.

    Advantages and Disadvantages

    The primary advantages of these storage solutions include a durable stainless steel construction, low evaporation loss rate, and comprehensive safety mechanisms such as safety valves and pressure gauges. However, a potential downside could be the higher initial investment compared to conventional storage tanks, though this is offset by the long-term efficiency and safety they provide.

    Product Usage in the Field

    These liquid nitrogen storage units are utilized extensively in biomedical laboratories, research facilities, and industrial applications. Their ability to efficiently manage and discharge liquid nitrogen makes them invaluable for tasks requiring precise temperature control and storage of sensitive biological materials.

    Recommendations

    To maximize the longevity and performance of your LN2 storage solution, it is advisable to regularly check and calibrate pressure gauges and safety valves. Routine maintenance and professional inspections will ensure the unit operates safely and efficiently over its lifespan. For immediate assistance and to explore the full range of features, consider requesting a quote or generating one automatically through the Kalstein Plus platform.

    Features

    • Welded stainless steel construction
    • Pressure generation for efficient nitrogen discharge
    • Available capacities from 5 to 500 liters
    • Equipped with decant valves and safety mechanisms
    • Low evaporation loss rate
    • Comprehensive pressure specifications

    Technical Specifications

    Model YR05423 YR05424 YR05425 YR05426 YR05427 YR05428 YR05429 YR05430
    Performance
    LN volume (L) 5 15 30 50 100 150 200 300
    Static Evaporation (L/Day) 0.15 0.38 0.75 1 1.3 1.95 2.4 3.3
    LN output (l/min) 2 2 3 3 4 6 8 8
    Dimensions
    Height (mm) 510 750 879 991 1185 1188 1265 1459
    Outer diameter (mm) 329 404 454 506 606 706 758 857
    Curb weight (kg) 15 23 32 54 75 102 130 202
    Complete weight (kg) 19.1 35.3 56.6 95 157 225 296 448
    Shipping weight (kg) 28 34 47 63 98 132 164 232
    Pressure parameters (MPA) 1. Standard working pressure 0.05,
    2. Maximum working pressure 0.09,
    3. First stage safety valve relief pressure 0.099,
    4. Second stage safety valve release pressure 0.15,
    5. Pressure gauge range 0~0.25
    1. Standard working pressure 0.05,
    2. Maximum working pressure 0.09,
    3. First stage safety valve relief pressure 0.099,
    4. Second stage safety valve release pressure 0.15,
    5. Gauge range 0~0.25,
    6. Rupture disc bursting pressure 0.47 .
    Model YR05431 YR05432 YR05433 YR05434 YR05435 YR05436 YR05437
    LN volume (L) 500 100 200 240 300 300 500
    Static Evaporation (L/Day) 5.5 1.3 2.4 2.9 3.3 3.3 5.5
    LN output (l/min) 10 4 8 8 8 8 10
    Height (mm) 1576 1185 1265 1350 1459 1459 1576
    Outer diameter (mm) 1008 606 758 758 857 857 1008
    Curb weight (kg) 255 75 130 148 202 202 255
    Complete weight (kg) 665 157 296 350 448 448 665
    Shipping weight (kg) 324 98 164 177 232 232 324
    Pressure parameters (MPA) 1. Standard working pressure 0.05,
    2. Maximum working pressure 0.09,
    3. First stage safety valve relief pressure 0.099,
    4. Second stage safety valve release pressure 0.15,
    5. Gauge range 0-0.25,
    6. Rupture disc bursting pressure 0.47 .
    1. Standard working pressure 0.05,
    2. Maximum working pressure 0.09,
    3. First stage safety valve relief pressure 0.099,
    4. Second stage safety valve release pressure 0.15,
    5. Gauge range 0~0.25
    1. Standard working pressure 0.05,
    2. Maximum working pressure 0.09,
    3. First stage safety valve relief pressure 0.099,
    4. Second stage safety valve release pressure 0.15,
    5. Gauge range 0-0.25,
    6. Rupture disc bursting pressure 0.47 .

    Contact us

    Need a quote, have questions about this product or want to clarify any doubt? Contact us.

    Frequently asked questions

    Want to know the air shipping cost to your facility?

    Place your address in the payment section and you'll automatically see the shipping to your door.

    I'm an institution; I need the price for multiple units

    Request a personalized quote in the contact section once you identify the model.

    More answers