Description
The Electrolyte Analyzer YR06396 // YR06406 is a sophisticated instrument engineered for the precise and dependable measurement of electrolytes across diverse clinical samples. Equipped with automated software to monitor and correct electrical potential, it ensures stability in performance. The device efficiently identifies and eliminates tiny bubbles, preventing blockages and maintaining accuracy in measurements. Its real-time diagnostics and automatic detection of residual liquids with alerts enhance operational safety, making it an ideal choice for busy clinical laboratories.
Market Price
The Electrolyte Analyzer YR06396 // YR06406 is priced between $2,100 and $6,800 USD, dependent on the provider and any additional specifications requested. This range reflects the advanced technology and superior performance features of the device. For an exact quote tailored to your needs, take advantage of our Kalstein Plus platform, providing competitive pricing and financing options to suit your laboratory requirements.
Frequently Asked Questions
- What types of samples can be analyzed by the YR06396 // YR06406?
This device is compatible with serum, plasma, whole blood, and diluted urine samples.
- How many test results can the YR06396 // YR06406 store?
The analyzer’s memory can hold up to 10,000 test results.
- What is the measurement speed of the YR06396 // YR06406?
Measurements are completed in less than 30 seconds, ensuring fast and efficient workflow.
Advantages and Disadvantages
Advantages:
- High Precision: Automatic liquid level detection and bubble filtration ensure accurate results.
- Efficiency: With automatic calibration and two-point corrections.
- Flexibility: Capable of analyzing multiple sample types.
- Safety: Power failure protection and sophisticated diagnostic tools.
Disadvantages:
- Initial Cost: The investment might be high for smaller laboratories.
- Regular Maintenance: Requires consistent calibration and use of consumables.
Field Use
Widely utilized in clinical and hospital laboratories, the Electrolyte Analyzer YR06396 // YR06406 excels in high-volume sample testing and rapid result delivery, making it perfect for demanding environments. Its automated calibration, bubble detection, and power failure protection enhance workflow efficiency and reliability, boosting overall laboratory productivity.
Recommendations
To maintain optimal performance of the Electrolyte Analyzer YR06396 // YR06406, adhere to regular maintenance schedules and follow the manufacturer’s guidelines. Ensure that the operating environment stays within 10-30°C and relative humidity below 80% for best results. Staff training on the proper usage can further ensure the accuracy and longevity of the device. For more details and to request a tailored quote, visit our Kalstein Plus platform and discover competitive pricing options.
Technical Specifications
Model | YR06396 | YR06397 | YR06398 | YR06399 | YR06400 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Analysis Method | ion selective electrode(ISE) | ||||
Measuring time | ≤30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Temperature | 10-30°C | ||||
Relative Humidity | 80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na CI TCO, AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO₂ AG | K Na Cl Li |
Model | YR064001 | YR06402 | YR06403 | YR06404 | YR06405 | YR06406 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Analysis Method | ion selective electrode(ISE) | |||||
Measuring time | ≤30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Temperature | 10-30°C | |||||
Relative Humidity | 80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li |
Model | Description |
YRA264 | K Electrode |
YRA265 | K Electrode |
YRA266 | Cl Electrode |
YRA267 | Ca Electrode |
YRA268 | pH Electrode |
YRA269 | Li Electrode |
YRA270 | Mg Electrode |
YRA271 | Ref. Electrode |
YRA272 | Reagent Pack Calibration A 430ml; Calibration B 110ml; ( For Model H900 only) |
YRA273 | Reference Electrode Internal Solution – 10ml |
YRA274 | Electrode Internal
Solution – 3ml |
YRA275 | Activating Solution – 110ml |
YRA276 | QC Solution Level 2
(Water-based) – 110ml |
YRA277 | Cleaning Solution – 110ml |
YRA278 | Electrode Wash Solution (Protein Enzyme) -125mg (25mg/bottle x5) |
YRA278-1 | Electrode Wash Solution (Diluent) – 5ml ( 1 bottle) |