Description
- Safety EO gas puncture device
EO gas can automatically punctured by special device in the chamber, no need human intervention.
- Efficient ventilation system
Automatic pulse vacuum ventilation ensures EO gas exhaust thoroughly .
- Full automatic control system
One button to control from start to end and finish automatically with printing record.
- Door interlock
The door cannot be opened while program is running.
- Display condition
It shows temperature, humidity, pressure, sterilization time, residual gas handle time and frequency.
- Sterilization chamber
The sterilization chamber adopts stainless steel 304 three-layer temperature control protection.
- Door
Double protective door, automatic vertical sliding door, safety interlocking door
- Printer
Print record for the sterilizing information of whole process, to prepare for verification.
- Humidity sensor
Inner humidity sensor check chamber humidity automatically, ensures chamber humidity keep in stable level.
- Pressure sensor
Inner with pressure sensor to check chamber pressure automatically, ensure that the chamber pressure is accurate and effective.
- Temperature sensor
Inner with temperature sensor to check chamber temperature automatically, ensure the chamber temperature within precise range of 50℃ ± 5℃.
- Vacuum system
Adapting the oil free vacuum pump, simple and convenient, the vacuum speed is fast and the service life is long.
- Negative pressure in whole cycle
Chamber pressure is always negative in whole cycle ensures EO gas no leakage to outside during working
- Heating system
Adapting to anti-explosion electric heating device, more convenient and fast.
- Variety of protective function
It has over temperature protection function and residual gas automatic process system. While the errors happen it have sound alarm. When the whole sterilization finished, have sound reminder also. Leak detection function and safety automatic detection function.
- Automatic recovery function
Regardless of power cut, outage, or the program disorder, it can determine the point of failure, the program can automatic recovery after power on and the device continue running.
- Fault diagnosis
Automatic fault detection, fault code content display alarm, fault sound alarm and fault printing system.
- Air inlet
The air inlet is provided with a sterile filter,which can effectively filter out bacteria and microorganisms,and avoid the second time pollution when discharged.
Technical Specifications
Model | YR05754 | YR05755 | YR05756 | YR05757 | YR05758 |
Door Type | Vertical sliding door | ||||
Heating Method | Electric uniform heating | ||||
Sterilization Temperature | 50 ℃ ± 5 ℃ | ||||
Working Pressure | -60 kpa | ||||
Sterilization Humidity | 45-75% | ||||
Sterilization Agent | EO gas | ||||
Chamber Material | Stainless steel / Aluminium | ||||
Shell Material | Steel plate baking varnish | ||||
Touch Screen | 7 Inch | ||||
Control System | PLC | ||||
Incubator | Constant temperature incubator | ||||
Power Supply | 110-220V / 50-60Hz | ||||
Capacity | 50L | 100L | 168L | 200L | 300L |
Weight | 154 | 170 | 210 | 230 | 298 |
Package | 84*73*150 | 84*84*178 | 88*120*185 | 122*90*188 | 125*92*196 |