Description
The Patient Monitors YR02176 is a state-of-the-art device designed for use in operating theaters and intensive care units. Featuring a 15-inch LCD screen, this modular monitor provides standard parameters like ECG, SPO2, TEMP, NIBP, RESP, and PR/HR. It offers a configurable setup including a 5-lead ECG, and optional features such as Masimo/Nellcor SpO2 and Suntech NIBP, making it adaptable to various critical care needs. With high accuracy and responsive alarms, it ensures precise patient monitoring. Ready to enhance your hospital’s monitoring capabilities? Request a quote now on Kalstein Plus.
Market Price
The Patient Monitors YR02176 generally falls in the price range of $4000 to $5000 USD in the market. This range reflects the high-quality and advanced features packed into the device, making it a worthwhile investment for healthcare facilities looking to upgrade their monitoring systems.
Frequently Asked Questions
What is the warranty period for the Patient Monitors YR02176? Typically, it comes with a one-year manufacturer warranty, covering any defects or issues.
Can the monitor be wall-mounted or used on a trolley? Yes, it comes with optional accessories for wall mounting or use with a trolley for convenient mobility and placement.
Advantages and Disadvantages
One of the main advantages of the Patient Monitors YR02176 is its modular design, allowing for customization based on the specific needs of the medical facility. Additionally, its high accuracy and range of parameter monitoring make it an essential tool in critical care. However, one potential downside could be the initial setup complexity due to its wide array of features. Nevertheless, the benefits of acquiring such a comprehensive monitoring system far outweigh the learning curve involved.
Product Use in the Field
This patient monitor is extensively used in operating theaters and ICU settings because of its robust capability to track and display vital signs in real-time. Surgeons and medical staff rely on its accuracy and reliability during surgical procedures and post-operative care, ensuring patient safety and optimal recovery outcomes.
Recommendations
To maximize the performance of the Patient Monitors YR02176, ensure regular calibration and maintenance checks. Familiarize medical staff with its interface and custom alarm settings to leverage its full potential, especially in high-stakes environments like the ICU.
Features
- 15-inch LCD screen for clear visibility
- Configurable with standard and optional modules
- Real-time monitoring with responsive alerts
- Optional accessories for mobility and custom installations
- Comprehensive parameter tracking including ECG, SPO2, and more
Technical Specifications
Model | YR02176 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | x250, x500, x1000, x2000 | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 20~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |