Description
The Pulsed Xenon lamp Benchtop Spectrophotometer YR05475 is an innovative measurement instrument engineered by Kalstein for performing precise color and appearance analyses across diverse laboratory and research applications. Highlighted by its durable pulsed xenon lamp, this spectrophotometer guarantees stability and longevity in every test. The YR05475 is integrated with a 7-inch TFT touchscreen and employs reflective d/8 and transmissive d/0 optical geometry, suitable for samples with or without the UV component. Featuring a dual-array 256-element CMOS sensor and automatic aperture identification system, the device assures high accuracy on both solid and liquid samples. With a storage capacity of up to 20,000 records and powerful PC software, it’s the optimal choice for R&D environments demanding consistent and detailed results.
Market Price
The pricing for the YR05475 spectrophotometer models ranges between $10,400 and $11,200 USD, providing a competitive and economically viable option compared to other premium models on the market. This equipment is indispensable for companies requiring precise quality control, particularly within industries such as plastics, paint, food, cosmetics, and medicine, where precise color analysis is vital. Leverage the Kalstein Plus platform today to receive a personalized, obligation-free quote tailored to your specific industry needs.
Frequently Asked Questions
- Is the YR05475 suitable for measuring both translucent and opaque samples?
Yes, this spectrophotometer is adept at analyzing both opaque and translucent materials, including liquids and transparent solids. - What is the storage capacity of the YR05475?
This model allows for the storage of up to 20,000 results, facilitating extensive and detailed test data tracking. - Is it possible to adjust the measurement aperture?
Yes, the YR05475 offers three adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm), providing flexibility in analyzing different sample types.
Advantages and Disadvantages
The YR05475 presents numerous advantages, such as a temperature compensation system that ensures accuracy even under varying environmental conditions. It offers comprehensive lighting options including both LED and UV, and an ergonomic design that supports extended use in demanding environments. However, potential users should note that periodic calibrations might be required to maintain optimal accuracy under high-use conditions.
Field Use
This spectrophotometer is the perfect solution for quality control and product development laboratories within high-demand sectors such as automotive, cosmetics, medical, and food industries. With its capability to measure both reflectance and transmittance across various materials, the YR05475 optimizes quality verification processes while sustaining high standards across all production stages.
Recommendations
To maximize the performance and longevity of the YR05475, regular calibrations along with maintaining the device in a clean, stable environment are advised. Adjusting the measurement aperture based on the sample type and specific testing conditions will ensure the highest accuracy and consistent results. Request your personalized quote now through Kalstein Plus and discover how the YR05475 Desktop Spectrophotometer can transform your quality control and color analysis processes, delivering precise and reliable measurements in every application.
Features
- Pulsed Xenon Lamp for long service life.
- 7-inch TFT Capacitive Touch Display.
- Dual-array 256-element CMOS sensor.
- Automatic aperture identification system.
- High accuracy and extended data storage.
Technical Specifications
Model | YR05475 (Pulsed xenon lamp) |
Optical Geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003) | |
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
Integrating Sphere Size | Φ 154mm |
Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Pitch | 10nm |
Semiband Width | 5nm |
Reflectance Range | 0~200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE |
Transmittance: SCI&SCE | |
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) |
Observer Angle | 2° & 10° |
Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Size | 370×300×200mm |
Weight | About 9.6kg |
Power Supply | DC 24V, 3A Power Adapter |
Light Source Device Life | 5 years, more than 3 million times measurements. |
Display | 7″ TFT Capacitive Screen-touch Display |
Data Port | USB & Print serial port |
Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, |
Optional Accessory | Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |