The YR06217 Neonatal LED Phototherapy Unit is an essential piece of medical equipment used for treating jaundice in newborns through effective light therapy. Understanding the technical terms associated with this device is crucial for healthcare professionals to ensure optimal use and patient safety. This article will provide a comprehensive glossary of terms related to the YR06217, along with practical insights into how they relate to its operation.
Understanding the YR06217 Neonatal LED Phototherapy Unit
The YR06217 unit employs a blue or LED tube light source to deliver phototherapy, a treatment essential for managing high bilirubin levels in infants. The equipment supports a digital timer for therapy visualization, along with a mobile stand and an adjustable radiant head that can pivot at various angles (30°, 60°, 90°). Such features enhance the therapy's effectiveness and allow for adaptable treatment settings.
Technical Specifications of YR06217
| Specification | Details |
|---|---|
| Model | YR06217 |
| Input Power | <150VA |
| Light Source | Blue tube/LED tube |
| Effective Life of Light Source | 2000/50000 hours |
| Wavelength | 400-550 nm |
| Irradiance Treatment Distance | 10~500px |
| Effective Area | 1125px×600px |
| Maximum Bilirubin Total Irradiance (Ebi max) | ≥2000μW/cm2 |
| Effective Area Surface | ≥500μW/cm2 |
| Average in Effective Area Surface | ≥400μW/cm2 |
| Uniformity of Ebi | 0.4 |
| Infrared Radiation in Effective Area | ≤10mW/cm2 (760nm<λ≤1400nm) |
| Ultraviolet Radiation in Effective Area | ≤1.0×10-5mW/cm2 (180nm<λ≤400nm) |
| Time Display Accuracy | 2h±1min |
| Operating Noise | ≤55dB(A) |
| Basic Performance | Equipment total irradiance (Ebi) ≥500μW/cm2 |
| Time Display Range | 9999h 59min |
| Adjust Angle | 30°, 60°, 90° |
| Adjust Height | 1100mm~1500mm |
Technical Glossary for YR06217
| Term | Definition |
|---|---|
| Phototherapy | A medical treatment that uses light to reduce bilirubin levels in newborns suffering from jaundice. |
| Bilirubin | A yellow compound in the blood that can cause jaundice if present in high levels. |
| LED (Light Emitting Diode) | A semiconductor device that emits light when an electric current passes through it, used in the YR06217 for effective phototherapy. |
| Irradiance | The power of the light source per unit area, crucial for determining the effectiveness of phototherapy. |
| Wavelength | The distance between successive peaks of a wave, relevant to the color of light used in phototherapy. |
| Effective Area | The surface area where the light emitted is sufficient to achieve therapeutic effects. |
| Uniformity of Ebi | A measure of how evenly the light distribution occurs over the effective area. |
| Digital Timer | A feature that allows the operator to monitor the duration of therapy accurately. |
| Mobile Stand | A movable base that supports the YR06217 unit, allowing for placement flexibility in clinical settings. |
| Radiant Head | The part of the phototherapy unit that emits light, adjustable to accommodate different angles. |
| Effective Life | The operational lifespan of the light source before significant performance degradation occurs. |
| Ambient Noise | The background sound in the environment where the YR06217 is used, which should be lower than 40dB(A) for optimal operation. |
| Maximum Ebi | The highest total irradiance of bilirubin that the YR06217 can provide. |
| Adjustment Angles | The set angles (30°, 60°, 90°) at which the radiant head can be positioned to enhance treatment effectiveness. |
| Treatment Distance | The distance from the light source to the infant, important for ensuring optimal exposure. |
| Time Display Range | The maximum time setting for the digital timer, indicating the duration of therapy sessions. |
Frequently Asked Questions
What is the primary function of the YR06217 Neonatal LED Phototherapy Unit?
The primary function of the YR06217 Neonatal LED Phototherapy Unit is to provide effective treatment for jaundice in newborns by using light therapy to reduce elevated bilirubin levels in the blood.
How does the adjustable radiant head enhance the operation of the YR06217?
The adjustable radiant head allows healthcare professionals to position the light source at various angles (30°, 60°, 90°) to ensure the infant receives optimal exposure to the therapeutic light, adapting to different treatment scenarios.
What is the significance of the digital timer in the YR06217?
The digital timer is crucial for tracking the therapy duration, ensuring that the treatment is administered for the correct length of time, which is vital for effective phototherapy.
How does the YR06217 ensure safety during operation?
The YR06217 is designed with features that minimize risks, including an operating noise level that is compliant with clinical standards and a mobile stand for safe and flexible positioning.
What are the maintenance requirements for the YR06217?
The YR06217 requires regular checks of the light source's effective life, cleaning of the surface, and ensuring the digital timer is functioning accurately to maintain optimal performance.
How can I request a quote for the YR06217 Neonatal LED Phototherapy Unit?
You can request a quote for the YR06217 Neonatal LED Phototherapy Unit through our platform, where you can find further details and competitive pricing options.
Conclusion
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.