Technical Glossary and Key Terminology for the YR06219 Infant Phototherapy Unit
The YR06219 Infant Phototherapy Unit is a critical device utilized in neonatal care to treat jaundice in newborns using phototherapy. Understanding the technical terminology associated with this unit enhances operational efficiency and ensures compliance with safety and operational standards. This article provides a detailed glossary of terms pertinent to the YR06219, along with an overview of its specifications and operational characteristics.
Technical Specifications of the YR06219
| Specification | Details |
|---|---|
| Model | YR06219 |
| Input Power | <150VA |
| Light Source | Blue Tube |
| Light Source Effective Life | 1000 hours |
| Wave Length | 400-550 nm |
| Irradiance Treatment Distance | 10~500 px |
| Effective Area | 1125 px × 600 px |
| Infrared Radiation in Effective Area | ≤10 mW/cm2 (760 nm < λ ≤ 1400 nm) |
| Ultraviolet Radiation in Effective Area | ≤1.0 × 10-5 mW/cm2 (180 nm < λ ≤ 400 nm) |
| Operating Noise | ≤55 dB(A) (ambient noise is lower than 40 dB(A)) |
| Basic Performance | ≥500 μW/cm2 |
Essential Terminology Related to YR06219
| Term | Definition |
|---|---|
| Phototherapy | A treatment method that uses light to decrease bilirubin levels in newborns with jaundice. |
| Bilirubin | A yellow compound produced during the normal breakdown of red blood cells, elevated levels can lead to jaundice. |
| Effective Irradiance | The amount of light energy delivered to the skin per unit area, crucial for effective treatment. |
| LED Light Source | A type of lighting that uses light-emitting diodes, known for efficiency and longevity. |
| Wave Length | The distance between successive peaks of a wave; in phototherapy, specific wavelengths are effective for treatment. |
| Ultraviolet Radiation | A form of electromagnetic radiation with wavelengths shorter than visible light, can be harmful in excess. |
| Infrared Radiation | Electromagnetic radiation with longer wavelengths than visible light, typically not absorbed by bilirubin. |
| Calibration | The process of adjusting the precision of the device to ensure accurate measurements of light intensity. |
| Ambient Noise | The background sound level in the area where the YR06219 is being operated, important for monitoring patient comfort. |
| Control System | The programmable interface that allows users to set and adjust treatment parameters. |
| Effective Area | The specific area where the light from the YR06219 is effective in providing treatment. |
Frequently Asked Questions
What is the purpose of the YR06219 Infant Phototherapy Unit?
The YR06219 Infant Phototherapy Unit is designed to treat neonatal jaundice by using specific wavelengths of light to lower bilirubin levels in the blood of infants. This helps avoid potential complications associated with jaundice.
How does the control system of the YR06219 work?
The control system of the YR06219 is programmable, allowing healthcare professionals to adjust the intensity of the lights based on the specific treatment needs of each patient. This ensures optimal therapy according to the individual condition of the infant.
What are the recommended maintenance procedures for the YR06219?
Regular maintenance of the YR06219 includes checking the light source for intensity and functionality, ensuring proper calibration of the device, and maintaining cleanliness around the unit to avoid contamination.
What are the indications for using the YR06219?
The primary indication for using the YR06219 is the treatment of infants diagnosed with hyperbilirubinemia or jaundice. Healthcare providers will assess bilirubin levels to determine the necessity for phototherapy treatment.
What safety features are included in the YR06219?
The YR06219 includes features such as an LCD screen indicating the accumulated working time and current time, ensuring caregivers can monitor usage effectively. Additionally, the built-in control system allows for safe adjustments of light intensity levels.
How do I interpret the readings from the YR06219?
Readings from the YR06219 indicate the intensity of light being delivered in specific wavelengths. Proper interpretation involves understanding how these readings correlate to bilirubin levels, which can be cross-referenced with clinical guidelines for jaundice treatment.
What should I do if the YR06219 displays an error code?
If the YR06219 displays an error code, refer to the user manual for troubleshooting steps. Common procedures include checking the power supply, ensuring all connections are secure, and re-calibrating the device to restore normal operation.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.