Description
The Electrolyte Analyzer YR06396 // YR06406 is an advanced device designed to provide precise and reliable results in the measurement of electrolytes in various clinical samples. This device is equipped with an automatic software for monitoring and correcting electrical potential to maintain stable performance. It effectively detects and filters tiny bubbles to avoid blockages and ensure accurate measurements. Additionally, real-time diagnostics of the system’s operating status and automatic residual liquid detection with corresponding alarms enhance operational safety.
The instrument features automatic calibration and two-point correction for slope and intercept adjustments, ensuring result accuracy. Thanks to the wave wash and direct pipe wash methods, it minimizes blockages and the risk of cross-contamination. With power failure protection, the analyzer can store up to 10,000 results, while its minimal consumption helps reduce consumable costs. This device is compatible with serum, plasma, whole blood, and diluted urine samples, and performs measurements in less than 30 seconds.
Market Price
The price of the Electrolyte Analyzer YR06396 // YR06406 varies depending on the provider and additional specifications required, generally ranging from $2,100 to $6,800 USD. This price range reflects the advanced technology used, high-performance capabilities, and additional features included in the device. To obtain an exact and personalized quote, we invite you to generate an automatic quote through our Kalstein Plus platform, where you can access competitive prices and financing options tailored to your needs.
Frequently Asked Questions
- What types of samples can the YR06396 // YR06406 analyze?
The YR06396 // YR06406 is compatible with serum, plasma, whole blood, and diluted urine samples.
- How many results can the YR06396 // YR06406 store?
The analyzer can store up to 10,000 test results in its memory.
- What is the measurement speed of the YR06396 // YR06406?
The device can perform measurements in less than 30 seconds.
Advantages and Disadvantages
Advantages:
- High Precision: Automatic liquid level detection and bubble filtration.
- Efficiency: Automatic calibration and two-point correction.
- Flexibility: Compatible with multiple types of samples and analysis methods.
- Safety: Power failure protection and fuzzy queries.
Disadvantages:
- Initial Cost: The investment may be high for some small laboratories.
- Dependence on Specific Technology: Requires regular consumables and calibrations.
Field Use
The Electrolyte Analyzer YR06396 // YR06406 is widely used in clinical and hospital laboratories for the precise measurement of electrolytes in various samples. Its ability to handle a high volume of samples and provide rapid results makes it ideal for high-demand environments. The integration of automatic calibration functions, bubble detection, and power failure protection ensures an efficient and reliable workflow, improving laboratory productivity and accuracy.
Recommendations
To maximize the performance of the Electrolyte Analyzer YR06396 // YR06406, regular maintenance and adherence to the manufacturer’s usage guidelines are recommended. Ensure that the operating environment meets the specified temperature and humidity conditions (10-30°C, <80% RH) to guarantee accurate results. Additionally, train staff in the proper use of the instrument to take full advantage of its features and maintain the quality of the analyses.
For more information and to request a personalized quote, visit our Kalstein Plus platform and get details on prices and financing options. Don’t miss the opportunity to improve the efficiency and precision in your laboratory with the YR06396 // YR06406.
Technical Specifications
Model | YR06396 | YR06397 | YR06398 | YR06399 | YR06400 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Analysis Method | ion selective electrode(ISE) | ||||
Measuring time | ≤30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Temperature | 10-30°C | ||||
Relative Humidity | 80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na CI TCO, AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO₂ AG | K Na Cl Li |
Model | YR064001 | YR06402 | YR06403 | YR06404 | YR06405 | YR06406 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Analysis Method | ion selective electrode(ISE) | |||||
Measuring time | ≤30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Temperature | 10-30°C | |||||
Relative Humidity | 80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO₂ AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO₂ AG | K Na Cl iCa nCa TCa pH Mg Li TCO₂ AG |
K Na Cl iCa nCa TCa pH Mg Li
|
Accessories
Model | Description |
YRA264 | K Electrode |
YRA265 | K Electrode |
YRA266 | Cl Electrode |
YRA267 | Ca Electrode |
YRA268 | pH Electrode |
YRA269 | Li Electrode |
YRA270 | Mg Electrode |
YRA271 | Ref. Electrode |
YRA272 | Reagent Pack Calibration A 430ml; Calibration B 110ml; ( For Model H900 only) |
YRA273 | Reference Electrode Internal Solution – 10ml |
YRA274 | Electrode Internal
Solution – 3ml |
YRA275 | Activating Solution – 110ml |
YRA276 | QC Solution Level 2
(Water-based) – 110ml |
YRA277 | Cleaning Solution – 110ml |
YRA278 | Electrode Wash Solution (Protein Enzyme) -125mg (25mg/bottle x5) |
YRA278-1 | Electrode Wash Solution (Diluent) – 5ml ( 1 bottle) |