Description
The Bedside Monitor YR02174 is a state-of-the-art 15-inch multi-parameter patient monitor designed to deliver comprehensive monitoring solutions in clinical settings. With a standard configuration that includes SpO2, RESP, NIBP, PR/HR, ECG, and 2-TEMP, this device ensures accurate and reliable monitoring of vital signs. Optional features like a 12-lead ECG, IBP, ETCO2, and a built-in printer provide versatility and adaptability to meet the diverse needs of healthcare professionals. Its sleek design and optional touch screen, wall mount, and trolley make it a user-friendly and efficient choice for any medical facility.
Market Price
In the market, the Bedside Monitor YR02174 is considered a mid-range product, with prices generally ranging from approximately 900 USD to 1,800 USD. This price range reflects its advanced technological capabilities and reliable performance, positioning it as a valuable investment for healthcare institutions looking to enhance their patient monitoring systems.
Frequently Asked Questions
What is included in the standard configuration of the Bedside Monitor YR02174?
The standard configuration includes SpO2, RESP, NIBP, PR/HR, ECG, and 2-TEMP monitoring.
Can the monitor be customized with additional features?
Yes, the Bedside Monitor YR02174 offers several optional features such as a 12-lead ECG, IBP, ETCO2, a printer, and a touch screen.
Advantages and Disadvantages
One of the main advantages of the Bedside Monitor YR02174 is its versatility in configuration, allowing customization based on specific patient monitoring needs. It is also praised for its accuracy and reliability. However, the high cost associated with some optional features may be considered a disadvantage for budget-conscious facilities.
Usage in the Field
In real-world scenarios, the Bedside Monitor YR02174 is utilized for continuous patient monitoring in various healthcare settings, including hospitals, clinics, and emergency rooms. Its comprehensive monitoring capabilities provide healthcare professionals with vital information to make informed medical decisions swiftly and effectively.
Recommendations
To maximize the use and lifespan of the Bedside Monitor YR02174, regular maintenance and calibration are advised. Ensure that all optional features are compatible with your facility’s needs and consider professional training for staff to utilize the monitor’s full capabilities efficiently.
Features
- 15-inch high-resolution display
- Standard configuration: SpO2, RESP, NIBP, PR/HR, ECG, 2-TEMP
- Optional 12 lead ECG, IBP, ETCO2, printer, touch screen
- User-friendly interface with optional touchscreen
- Connectivity options for enhanced data management
- Audio-video alarm system for critical updates
- Portable design with optional trolley and wall mount
Technical Specifications
Model | YR02174 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | 1.25, 2.5, 5.0, 10, 20, 40mm/mV, Auto. | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 20~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |