Description
The Fetal Monitor YR02190A is an advanced medical device equipped with a 12.1-inch color TFT screen that folds 90 degrees, offering optimal visibility and convenience. It features an impressive resolution of 800×600 and can display up to six waveforms simultaneously. Standard configurations include SpO2, MHR, NIBP, TEMP, ECG, RESP, TOCO, FHR, FM, and a recorder. Optional features include a fetal stimulator, a secondary FHR, and a trolley for enhanced functionality and mobility. This comprehensive monitoring solution is designed to deliver accurate and reliable data, making it an essential tool for prenatal care.
Market Price
When considering a purchase of a fetal monitor, it’s essential to understand the market pricing. The Fetal Monitor YR02190A is competitively positioned within a price range of 2200 USD to 2900 USD. This variance depends on optional configurations and additional features. We invite you to explore our Kalstein Plus platform to generate an automatic quote and discover the best purchasing options tailored to your specific needs.
Frequently Asked Questions
What is the frequency response of the FHR function?
The FHR function operates at a working frequency of 1.0MHz, ensuring precise measurements.
Is the device portable?
Yes, the monitor’s folding screen and optional trolley enhance its portability, making it suitable for various healthcare settings.
Can I customize the configurations?
Certainly, the monitor offers optional configurations such as a fetal stimulator and additional features to customize it according to your requirements.
Advantages and Disadvantages
Advantages: The Fetal Monitor YR02190A is user-friendly, providing comprehensive monitoring capabilities with high accuracy. Its folding screen and optional mobility features make it a versatile choice for clinics and hospitals.
Disadvantages: While highly functional, incorporating optional features can increase the overall cost, which is a consideration for budget-conscious buyers.
Product Use in the Field
The Fetal Monitor YR02190A is typically used in hospitals and clinics to monitor fetal health during pregnancy. Its precision in tracking fetal heart rate, contractions, and other vital signs provides critical data that aids healthcare professionals in assessing fetal well-being and making informed decisions.
Recommendations
For optimal performance, it is recommended to routinely calibrate the device and ensure all sensors are functioning correctly. Using the monitor within the specified temperature range of +5°C to +40°C will maintain its accuracy and longevity. Additionally, explore Kalstein Plus for assistance with setup and maintenance inquiries.
Features
- 12.1 inches color TFT screen with 90-degree folding
- Resolution: 800×600
- Displays up to 6 waveforms
- Standard configurations include SpO2, MHR, NIBP, TEMP, ECG, RESP, TOCO, FHR, FM, and Recorder
- Optional features: Fetal Stimulator, FHR2, Trolley
- User-friendly interface
Technical Specifications
Model | YR02190A |
FHR | |
Strength | < 5mW/cm2 |
Working Frequency | 1.0MHz |
Signal Processing | Special DSP system and modern recognition |
Measurement Range | 50~240bpm |
Alarm Range: | High Limit: 160, 170, 180, 190 bpm Low Limit: 90, 100, 110, 120 bpm |
Maximum Audio Output Power | 1.5 Watt |
TOCO | |
Measurement Range | 0-100 units |
SpO2 | |
Measurement Range | 70%~99% |
Measure Accuracy | ±3% error |
HR | |
Measurement Range: | 30bpm~240bpm |
Measure Accuracy | ±2 bpm |
NIBP | |
Measurement Range | SYS 6.7~32.0kPa(50~240mmHg) MEAN: 3.4~26.6kPa(25~200mmHg) DIA: 2.0~24.0ka(15~180mmHg) |
NIBP Accuracy | ±1.1kPa(±8mmHg)or ±5% of results, taking the bigger one |
HR Measurement Range: | 40bpm~240bpm |
HR Measure Accuracy | ±2 bpm or ±5% of the results, taking the bigger one. |
Measure Mode | Manual to start/stop NIBP measurement |
Temperature | |
Arrange: | 0~50 ℃ |
Resolution | 0.1 ℃ |
Accuracy | 0.1 ℃( excluded the error caused by transducer) |
ENVIRONMENT | |
Working Environment | Temperature: +5℃ ~ +40℃ |
Atmospheric Pressure | 86kPa ~ 106kPa |
Transport and Storage Temperature: | Humidity: < 93% Atmospheric Pressure: 86kPa ~ 106kPa |